AC Electrical Wiring to for a common V- for PSUs

This commit is contained in:
GadgetAngel
2022-01-06 19:51:14 -05:00
parent 4921744bac
commit 2bdfcefff3
20 changed files with 50 additions and 10 deletions

View File

@ -1,3 +1,3 @@
version https://git-lfs.github.com/spec/v1
oid sha256:9f9e03570c45dbc862f8fd5b4234f24fd2bbee011699b6340c15dc1236f94ca4
size 75012842
oid sha256:8d5a2e0dada580047b5656fc0dcb00e04a66ae4682ba808293ecea25fe9009c6
size 75433409

View File

@ -135,7 +135,7 @@ Below you will find the JPG and the PDF files for the "Voron 2.4 AC Electrical W
After finding a [schematic diagram of the BTT relay V1.2 from a russian website](https://github.com/GadgetAngel/Voron2.4_My_Build_Log/blob/main/Resources/BTT%20Relay%20V1.2%20Schematic.pdf) I have become aware that I can control the PSUs witht the Raspberry Pi via the BTT Relay V1.2 modules with the use of a second relay module. Therefore the secondary relaymodule will only control the mechanical Hour-Counter. I have updated my AC Electrical Wiring Diagram to reflect this change.
After a discussion in the discord channel with other more experience Voron users the following question arose: "Does your printer even have the capacity to resume print? If the Gantry sags at all it won't, since you wouldn't be able to perform QGL with a buildplate already occupied.". Due to this fact using the BTT UPS modules is now out since I will not be able to get the flying gantery back to where it needs to be to resume a print. I will be removing the "resume after power failure" as a requirement for my Voron 2.4 printer.
After a discussion in the Voron discord channel with other more experience Voron users the following question arose: "Does your printer even have the capacity to resume print? If the Gantry sags at all it won't, since you wouldn't be able to perform QGL with a buildplate already occupied.". Due to this fact using the BTT UPS modules is now out since I will not be able to get the flying gantery back to where it needs to be to resume a print. I will be removing the "resume after power failure" as a requirement for my Voron 2.4 printer.
## A Picture of the "Voron 2.4 AC Electrical Wiring Diagram" for QUEEN:

View File

@ -1,3 +1,3 @@
version https://git-lfs.github.com/spec/v1
oid sha256:ba85cc798b8648e5d394d44f631c31c7130d530bbad7abaa6691e87723f120f1
oid sha256:1570478f49b5d89a472d68945e4a7ed38c4909a5d3c06ad44b58b7c40c117e40
size 6061692

View File

@ -1,3 +1,3 @@
version https://git-lfs.github.com/spec/v1
oid sha256:0fb4391a34df376c739f67c3bfeee3cf6ce343d18207620c15eaa0c1a1a1ce18
size 4013459
oid sha256:86129748dbea929b87388413074bdafec4cff13ae52ecefd7023a3348a02a23c
size 3832236